Home > Products > Magnet Wire > Products > Specification

Specification

These are Daikoku Standard Specifications,If you have special request, please contact us.

Copper wire

Copper wire(Class 2 and Class 3)

Size
[mm]
Conductor
dia.
[mm]
Conductor
resistance
[Ω/m]
(20℃)
Class 2 Class 3
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Insulation Bonding Insulation Bonding
0.020 -
(*1)
53.8

57.4
0.0280

0.0300
0.0240

0.0260
(*2)
0.0015 309,000 0.0260

0.0280
0.0240

0.0260
(*2)
0.001 320,000
0.025 -
(*1)
34.2

36.8
0.0335

0.0365
0.0285

0.0315
(*2)
0.0015 202,000 0.0310

0.0340
0.0290

0.0310
(*2)
0.001 210,000
0.030 0.030
±
0.001
22.8

26.1
0.039

0.043
0.002 0.002 142,000 0.037

0.040
0.002 0.001 145,000
0.035 0.035
±
0.001
16.9

19.0
0.044

0.048
0.002 0.002 106,000 0.042

0.045
0.002 0.001 108,000
0.040 0.040
±
0.001
13.0

14.5
0.050

0.055
0.002 0.002 81,000 0.048

0.052
0.002 0.001 82,000
0.045 0.045
±
0.001
10.3

11.4
0.055

0.060
0.002 0.002 65,000 0.0053

0.057
0.002 0.001 66,000
0.050 0.050
±
0.002
8.11

9.53
0.061

0.067
0.003 0.003 52,000 0.060

0.064
0.003 0.0015 53,000
0.055 0.055
±
0.002
6.75

7.83
0.066

0.073
0.003 0.003 44,000 0.065

0.069
0.003 0.0015 45,000
0.060 0.060
±
0.002
5.71

6.53
0.071

0.078
0.003 0.003 37,000 0.070

0.075
0.003 0.0015 38,000
0.065 0.065
±
0.002
4.89

5.54
0.077

0.084
0.003 0.003 31,000 0.075

0.080
0.003 0.0015 31,500
0.070 0.070
±
0.002
4.23

4.75
0.082

0.090
0.003 0.003 27,000 0.080

0.085
0.003 0.0015 27,500
0.075 0.075
±
0.002
3.70

4.13
0.088

0.096
0.003 0.003 23,500 0.085

0.090
0.003 0.002 24,000
0.080 0.080
±
0.002
3.26

3.61
0.093

0.101
0.003 0.003 21,000 0.091

0.097
0.003 0.002 21,000
0.085 0.085
±
0.002
2.90

3.19
0.098

0.106
0.003 0.003 18,500 0.096

0.102
0.003 0.002 18,500
0.090 0.090
±
0.002
2.59

2.84
0.103

0.111
0.003 0.003 16,500 0.101

0.107
0.003 0.002 16,500
0.095 0.095
±
0.002
2.33

2.54
0.109

0.117
0.003 0.003 15,000 0.106

0.112
0.003 0.002 15,000
0.100 0.100
±
0.002
2.10

2.29
0.114

0.122
0.003 0.003 14,000 0.111

0.118
0.003 0.002 14,000

*1 Conductor diameter is controlled by conductor resistance.
*2 Film thickness of insulation is controlled by insurated diameter.
*3 Wire length calculated at target dimentions is mentioned as reference. This is not specified value.
*4 Standard mesurement pressure of micrometer is as follows.
  Size < 0.030mm:0.7N
  Size ≥ 0.030mm:3.0N

 

DHT wire

DHT wire(Class 2 and Class 3)

Size
[mm]
Conductor dia.
[mm]
Conductor
resistance
[Ω/m]
(20℃)
Class 2 Class 3
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Insulation Bonding Insulation Bonding
0.020 -
(*1)
53.8

57.4
0.0280

0.0300
0.0240

0.0260
(*2)
0.0015 309,000 0.0260

0.0280
0.0240

0.0260
(*2)
0.001 320,000
0.025 -
(*1)
34.2

36.8
0.0335

0.0365
0.0285

0.0315
(*2)
0.0015 202,000 0.0310

0.0340
0.0290

0.0310
(*2)
0.001 210,000
0.030 0.030
±
0.001
24.39
±
5%
0.039

0.043
0.002 0.002 142,000 0.037

0.040
0.002 0.001 145,000
0.035 0.035
±
0.001
17.92
±
5%
0.044

0.048
0.002 0.002 106,000 0.042

0.045
0.002 0.001 108,000
0.040 0.040
±
0.001
13.72
±
5%
0.050

0.055
0.002 0.002 81,000 0.048

0.052
0.002 0.001 82,000
0.045 0.045
±
0.001
10.84
±
5%
0.055

0.060
0.002 0.002 65,000 0.0053

0.057
0.002 0.001 66,000
0.050 0.050
±
0.002
8.78
±
5%
0.061

0.067
0.003 0.003 52,000 0.060

0.064
0.003 0.0015 53,000
0.055 0.055
±
0.002
7.26
±
5%
0.066

0.073
0.003 0.003 44,000 0.065

0.069
0.003 0.0015 45,000
0.060 0.060
±
0.002
6.10
±
5%
0.071

0.078
0.003 0.003 37,000 0.070

0.075
0.003 0.0015 38,000
0.065 0.065
±
0.002
5.20
±
5%
0.077

0.084
0.003 0.003 31,000 0.075

0.080
0.003 0.0015 31,500
0.070 0.070
±
0.002
4.48
±
5%
0.082

0.090
0.003 0.003 27,000 0.080

0.085
0.003 0.0015 27,500
0.075 0.075
±
0.002
3.90
±
5%
0.088

0.096
0.003 0.003 23,500 0.085

0.090
0.003 0.002 24,000
0.080 0.080
±
0.002
3.43
±
5%
0.093

0.101
0.003 0.003 21,000 0.091

0.097
0.003 0.002 21,000
0.085 0.085
±
0.002
3.04
±
5%
0.098

0.106
0.003 0.003 18,500 0.096

0.102
0.003 0.002 18,500
0.090 0.090
±
0.002
2.71
±
5%
0.103

0.111
0.003 0.003 16,500 0.101

0.107
0.003 0.002 16,500
0.095 0.095
±
0.002
2.43
±
5%
0.109

0.117
0.003 0.003 15,000 0.106

0.112
0.003 0.002 15,000
0.100 0.100
±
0.002
2.20
±
5%
0.114

0.122
0.003 0.003 14,000 0.111

0.118
0.003 0.002 14,000

*1 Conductor diameter is controlled by conductor resistance.
*2 Film thickness of insulation is controlled by insurated diameter.
*3 Wire length calculated at target dimentions is mentioned as reference. This is not specified value.
*4 Standard mesurement pressure of micrometer is as follows.
  Size < 0.030mm:0.7N
  Size ≥ 0.030mm:3.0N

 

GDHT wire

GDHT wire(Class 2 and Class 3)

Size
[mm]
Conductor dia.
[mm]
Conductor
resistance
[Ω/m]
(20℃)
Class 2 Class 3
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Insulation Bonding Insulation Bonding
0.020 -
(*1)
57.77
±
4%
0.0280

0.0300
0.0240

0.0260
(*2)
0.0015 309,000 0.0260

0.0280
0.0240

0.0260
(*2)
0.001 320,000
0.025 -
(*1)
36.97
±
4%
0.0335

0.0365
0.0285

0.0315
(*2)
0.0015 202,000 0.0310

0.0340
0.0290

0.0310
(*2)
0.001 210,000
0.030 0.030
±
0.001
25.67
±
4%
0.039

0.043
0.002 0.002 142,000 0.037

0.040
0.002 0.001 145,000
0.035 0.035
±
0.001
18.86
±
4%
0.044

0.048
0.002 0.002 106,000 0.042

0.045
0.002 0.001 108,000
0.040 0.040
±
0.001
14.37
±
4%
0.050

0.055
0.002 0.002 81,000 0.048

0.052
0.002 0.001 82,000
0.045 0.045
±
0.001
11.35
±
4%
0.055

0.060
0.002 0.002 65,000 0.0053

0.057
0.002 0.001 66,000
0.050 0.050
±
0.002
9.19
±
4%
0.061

0.067
0.003 0.003 52,000 0.060

0.064
0.003 0.0015 53,000
0.055 0.055
±
0.002
7.60
±
4%
0.066

0.073
0.003 0.003 44,000 0.065

0.069
0.003 0.0015 45,000
0.060 0.060
±
0.002
6.39
±
4%
0.071

0.078
0.003 0.003 37,000 0.070

0.075
0.003 0.0015 38,000
0.065 0.065
±
0.002
5.44
±
4%
0.077

0.084
0.003 0.003 31,000 0.075

0.080
0.003 0.0015 31,500
0.070 0.070
±
0.002
4.69
±
4%
0.082

0.090
0.003 0.003 27,000 0.080

0.085
0.003 0.0015 27,500
0.075 0.075
±
0.002
4.09
±
4%
0.088

0.096
0.003 0.003 23,500 0.085

0.090
0.003 0.002 24,000
0.080 0.080
±
0.002
3.59
±
4%
0.093

0.101
0.003 0.003 21,000 0.091

0.097
0.003 0.002 21,000
0.085 0.085
±
0.002
3.18
±
4%
0.098

0.106
0.003 0.003 18,500 0.096

0.102
0.003 0.002 18,500
0.090 0.090
±
0.002
2.82
±
4%
0.103

0.111
0.003 0.003 16,500 0.101

0.107
0.003 0.002 16,500
0.095 0.095
±
0.002
2.53
±
4%
0.109

0.117
0.003 0.003 15,000 0.106

0.112
0.003 0.002 15,000
0.100 0.100
±
0.002
2.29
±
4%
0.114

0.122
0.003 0.003 14,000 0.111

0.118
0.003 0.002 14,000

*1 Conductor diameter is controlled by conductor resistance.
*2 Film thickness of insulation is controlled by insurated diameter.
*3 Wire length calculated at target dimentions is mentioned as reference. This is not specified value.
*4 Standard mesurement pressure of micrometer is as follows.
  Size < 0.030mm:0.7N
  Size ≥ 0.030mm:3.0N

 

SDHT wire

SDHT wire(Class 2 and Class 3)

Size
[mm]
Conductor dia.
[mm]
Conductor
resistance
[Ω/m]
(20℃)
Class 2 Class 3
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Insulation Bonding Insulation Bonding
0.020 -
(*1)
60.31
±
5%
0.0280

0.0300
0.0240

0.0260
(*2)
0.0015 309,000 0.0260

0.0280
0.0240

0.0260
(*2)
0.001 320,000
0.025 -
(*1)
36.80
±
5%
0.0335

0.0365
0.0285

0.0315
(*2)
0.0015 202,000 0.0310

0.0340
0.0290

0.0310
(*2)
0.001 210,000
0.030 0.030
±
0.001
26.80
±
7%
0.039

0.043
0.002 0.002 142,000 0.037

0.040
0.002 0.001 145,000
0.035 0.035
±
0.001
19.69
±
7%
0.044

0.048
0.002 0.002 106,000 0.042

0.045
0.002 0.001 108,000
0.040 0.040
±
0.001
15.08
±
7%
0.050

0.055
0.002 0.002 81,000 0.048

0.052
0.002 0.001 82,000
0.045 0.045
±
0.001
11.91
±
7%
0.055

0.060
0.002 0.002 65,000 0.0053

0.057
0.002 0.001 66,000
0.050 0.050
±
0.002
9.65
±
7%
0.061

0.067
0.003 0.003 52,000 0.060

0.064
0.003 0.0015 53,000
0.055 0.055
±
0.002
7.97
±
7%
0.066

0.073
0.003 0.003 44,000 0.065

0.069
0.003 0.0015 45,000
0.060 0.060
±
0.002
6.70
±
7%
0.071

0.078
0.003 0.003 37,000 0.070

0.075
0.003 0.0015 38,000
0.065 0.065
±
0.002
5.71
±
7%
0.077

0.084
0.003 0.003 31,000 0.075

0.080
0.003 0.0015 31,500
0.070 0.070
±
0.002
4.92
±
7%
0.082

0.090
0.003 0.003 27,000 0.080

0.085
0.003 0.0015 27,500
0.075 0.075
±
0.002
4.29
±
7%
0.088

0.096
0.003 0.003 23,500 0.085

0.090
0.003 0.002 24,000
0.080 0.080
±
0.002
3.77
±
7%
0.093

0.101
0.003 0.003 21,000 0.091

0.097
0.003 0.002 21,000
0.085 0.085
±
0.002
3.34
±
5%
0.098

0.106
0.003 0.003 18,500 0.096

0.102
0.003 0.002 18,500
0.090 0.090
±
0.002
2.98
±
5%
0.103

0.111
0.003 0.003 16,500 0.101

0.107
0.003 0.002 16,500
0.095 0.095
±
0.002
2.67
±
5%
0.109

0.117
0.003 0.003 15,000 0.106

0.112
0.003 0.002 15,000
0.100 0.100
±
0.002
2.41
±
5%
0.114

0.122
0.003 0.003 14,000 0.111

0.118
0.003 0.002 14,000

*1 Conductor diameter is controlled by conductor resistance.
*2 Film thickness of insulation is controlled by insurated diameter.
*3 Wire length calculated at target dimentions is mentioned as reference. This is not specified value.
*4 Standard mesurement pressure of micrometer is as follows.
  Size < 0.030mm:0.7N
  Size ≥ 0.030mm:3.0N

 

VDHT wire

VDHT wire(Class 2 and Class 3)

Size
[mm]
Conductor dia.
[mm]
Conductor
resistance
[Ω/m]
(20℃)
Class 2 Class 3
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Insulation Bonding Insulation Bonding
0.030 0.030
±
0.001
28.04
±
4%
0.039

0.043
0.002 0.002 142,000 0.037

0.040
0.002 0.001 145,000
0.035 0.035
±
0.001
20.60
±
4%
0.044

0.048
0.002 0.002 106,000 0.042

0.045
0.002 0.001 108,000
0.040 0.040
±
0.001
15.68
±
4%
0.050

0.055
0.002 0.002 81,000 0.048

0.052
0.002 0.001 82,000
0.045 0.045
±
0.001
12.39
±
4%
0.055

0.060
0.002 0.002 65,000 0.0053

0.057
0.002 0.001 66,000
0.050 0.050
±
0.002
10.04
±
4%
0.061

0.067
0.003 0.003 52,000 0.060

0.064
0.003 0.0015 53,000
0.055 0.055
±
0.002
8.29
±
4%
0.066

0.073
0.003 0.003 44,000 0.065

0.069
0.003 0.0015 45,000
0.060 0.060
±
0.002
6.93
±
4%
0.071

0.078
0.003 0.003 37,000 0.070

0.075
0.003 0.0015 38,000
0.065 0.065
±
0.002
5.90
±
4%
0.077

0.084
0.003 0.003 31,000 0.075

0.080
0.003 0.0015 31,500
0.070 0.070
±
0.002
5.06
±
4%
0.082

0.090
0.003 0.003 27,000 0.080

0.085
0.003 0.0015 27,500
0.075 0.075
±
0.002
4.41
±
4%
0.088

0.096
0.003 0.003 23,500 0.085

0.090
0.003 0.002 24,000
0.080 0.080
±
0.002
3.88
±
4%
0.093

0.101
0.003 0.003 21,000 0.091

0.097
0.003 0.002 21,000
0.085 0.085
±
0.002
3.43
±
4%
0.098

0.106
0.003 0.003 18,500 0.096

0.102
0.003 0.002 18,500
0.090 0.090
±
0.002
3.06
±
4%
0.103

0.111
0.003 0.003 16,500 0.101

0.107
0.003 0.002 16,500
0.095 0.095
±
0.002
2.75
±
4%
0.109

0.117
0.003 0.003 15,000 0.106

0.112
0.003 0.002 15,000
0.100 0.100
±
0.002
2.48
±
4%
0.114

0.122
0.003 0.003 14,000 0.111

0.118
0.003 0.002 14,000

*1 Conductor diameter is controlled by conductor resistance.
*2 Film thickness of insulation is controlled by insurated diameter.
*3 Wire length calculated at target dimentions is mentioned as reference. This is not specified value.
*4 Standard mesurement pressure of micrometer is as follows.
  Size < 0.030mm:0.7N
  Size ≥ 0.030mm:3.0N

 

CCA wire

CCA wire(Class 2 and Class 3)

Size
[mm]
Conductor dia.
[mm]
Conductor
resistance
[Ω/m]
(20℃)
Class 2 Class 3
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*3)
[m/1,000gs]
Insulation Bonding Insulation Bonding
0.025 -
(*1)
52.42
±
5%
0.0335

0.0365
0.0285

0.0315
(*2)
0.0015 421,000 0.0310

0.0340
0.0290

0.0310
(*2)
0.001 446,000
0.030 0.030
±
0.001
36.40
±
7%
0.039

0.043
0.002 0.002 299,500 0.037

0.040
0.002 0.001 314,500
0.035 0.035
±
0.001
26.75
±
7%
0.044

0.048
0.002 0.002 228,500 0.042

0.045
0.002 0.001 238,500
0.040 0.040
±
0.001
20.48
±
7%
0.050

0.055
0.002 0.002 173,500 0.048

0.052
0.002 0.001 180,000
0.045 0.045
±
0.001
16.18
±
7%
0.055

0.060
0.002 0.002 136,500 0.0053

0.057
0.002 0.001 141,000
0.050 0.050
±
0.002
13.11
±
7%
0.061

0.067
0.003 0.003 113,000 0.060

0.064
0.003 0.0015 116,500
0.055 0.055
±
0.002
10.83
±
7%
0.066

0.073
0.003 0.003 95,500 0.065

0.069
0.003 0.0015 98,000
0.060 0.060
±
0.002
9.10
±
7%
0.071

0.078
0.003 0.003 81,500 0.070

0.075
0.003 0.0015 82,500
0.065 0.065
±
0.002
7.75
±
7%
0.077

0.084
0.003 0.003 69,500 0.075

0.080
0.003 0.0015 71,000
0.070 0.070
±
0.002
6.69
±
7%
0.082

0.090
0.003 0.003 60,000 0.080

0.085
0.003 0.0015 62,000
0.075 0.075
±
0.002
4.82
±
7%
0.088

0.096
0.003 0.003 52,500 0.085

0.090
0.003 0.0020 54,500
0.080 0.080
±
0.002
5.12
±
7%
0.093

0.101
0.003 0.003 46,500 0.091

0.097
0.003 0.002 47,500
0.085 0.085
±
0.002
4.53
±
7%
0.098

0.106
0.003 0.003 42,000 0.096

0.102
0.003 0.002 42,500
0.090 0.090
±
0.002
4.04
±
7%
0.103

0.111
0.003 0.003 37,500 0.101

0.107
0.003 0.002 38,000
0.095 0.095
±
0.002
3.63
±
7%
0.109

0.117
0.003 0.003 33,500 0.106

0.112
0.003 0.002 34,500
0.100 0.100
±
0.002
3.28
±
7%
0.114

0.122
0.003 0.003 30,500 0.111

0.118
0.003 0.002 31,500

*1 Conductor diameter is controlled by conductor resistance.
*2 Film thickness of insulation is controlled by insurated diameter.
*3 Wire length calculated at target dimentions is mentioned as reference. This is not specified value.
*4 Standard mesurement pressure of micrometer is as follows.
  Size < 0.030mm:0.7N
  Size ≥ 0.030mm:3.0N

 

DCCA wire

DCCA wire(Class 2 and Class 3)

Size
[mm]
Conductor dia.
[mm]
Conductor
resistance
[Ω/m]
(20℃)
Class 2 Class 3
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*1)
[m/1,000gs]
Overall diameter
[mm]
Min film thickness
[mm]
Wire length
(*1)
[m/1,000gs]
Insulation Bonding Insulation Bonding
0.030 0.030
±
0.001
39.03
±
7%
0.039

0.043
0.002 0.002 299,500 0.037

0.040
0.002 0.001 314,500
0.035 0.035
±
0.001
28.67
±
7%
0.044

0.048
0.002 0.002 228,500 0.042

0.045
0.002 0.001 238,500
0.040 0.040
±
0.001
21.95
±
7%
0.050

0.055
0.002 0.002 173,500 0.048

0.052
0.002 0.001 180,000
0.045 0.045
±
0.001
17.34
±
7%
0.055

0.060
0.002 0.002 136,500 0.0053

0.057
0.002 0.001 141,000
0.050 0.050
±
0.002
14.05
±
7%
0.061

0.067
0.003 0.003 113,000 0.060

0.064
0.003 0.0015 116,500
0.055 0.055
±
0.002
11.61
±
7%
0.066

0.073
0.003 0.003 95,500 0.065

0.069
0.003 0.0015 98,000
0.060 0.060
±
0.002
9.76
±
7%
0.071

0.078
0.003 0.003 81,500 0.070

0.075
0.003 0.0015 82,500
0.065 0.065
±
0.002
8.25
±
7%
0.077

0.084
0.003 0.003 69,500 0.075

0.080
0.003 0.0015 71,000
0.070 0.070
±
0.002
7.11
±
7%
0.082

0.090
0.003 0.003 60,000 0.080

0.085
0.003 0.0015 62,000
0.075 0.075
±
0.002
6.19
±
7%
0.088

0.096
0.003 0.003 52,500 0.085

0.090
0.003 0.002 54,500
0.080 0.080
±
0.002
5.36
±
7%
0.093

0.101
0.003 0.003 46,500 0.091

0.097
0.003 0.002 47,500
0.085 0.085
±
0.002
4.75
±
7%
0.098

0.106
0.003 0.003 42,000 0.096

0.102
0.003 0.002 42,500
0.090 0.090
±
0.002
4.23
±
7%
0.103

0.111
0.003 0.003 37,500 0.101

0.107
0.003 0.002 38,000
0.095 0.095
±
0.002
3.80
±
7%
0.109

0.117
0.003 0.003 33,500 0.106

0.112
0.003 0.002 34,500
0.100 0.100
±
0.002
3.43
±
7%
0.114

0.122
0.003 0.003 30,500 0.111

0.118
0.003 0.002 31,500

*1 Conductor diameter is controlled by conductor resistance.
*2 Film thickness of insulation is controlled by insurated diameter.
*3 Wire length calculated at target dimentions is mentioned as reference. This is not specified value.
*4 Standard mesurement pressure of micrometer is as follows.
  Size < 0.030mm:0.7N
  Size ≥ 0.030mm:3.0N

 
Return to the top